This database file can be imported in SCIA Engineer. It contains nonlinear functions for the Layher Allround diagonals with K2000+ couplers.

This database file can be imported in SCIA Engineer. It contains nonlinear functions for the Layher Allround diagonals with K2000+ couplers.

The Layher Allround Zulassung Z-8.22.64 describes spring resistances for tension and compression in Table 7 and design resistances for tension and compression forces in Table 8. Based on these tables nonlinear functions can be created, for example:

Instructions

Download the EP_NonLinearFunction_K2000+_H2000.db4 file to your computer.

Start a new SCIA Engineer project or open an existing project and go to the Nonlinear functions library (Main menu > Libraries > Structure and analysis > Nonlinear functions).

Click on Read database from file and select the downloaded EP_NonLinearFunction.db4 file:

Import the desired nonlinear functions or import all nonlinear functions in the project:

Now you can assign the nonlinear function as a hinge to both end of the desired diagonal(s).